Home -products-DT862 Three-phase watt-hour meters
p15
  • product name : DT862 Three-phase watt-hour meters
  • product brand : LBAJI
  • Place of Origin : CHINA
  • E-mail : sales@labji.com
  • Online Contact :
Detailed Instruction

Application

Three-phase watt-hour meter is that of inductance type, used for measuring three-phase AC active or reactiv eenergy of reference frequency 50Hz or 60Hz , DT862, DT864, DS862 and DS864 series are the three-phase active energy watt-hour meters,and DX862,DX864, DX865 and DX863 series are three­phase reactive energy watt-hour meters.

Produce Specification

Model

Name

Class index

Spec

Starting current

Connection w ay

DT862
3*220V/380V

Three-phase four-wire active energy watt-hour meter

2

3*1.5(6)A  3*3(6)A

0.5%/b

Connected through multi-purpose current transfomer

DT862
3*220V/380V

Three-phase four-wire active energy watt-hour meter

2

3*5(20)A  3*10 (40)A
3* 15(60)A  3*2 0(80)A 3*30(100)A

0.5%/b Direct connection

DT864
3*220V/380V

Three-phase four-wire active energy watt-hour meter

1

3*1.5(6)A  3*3(6)A

0.4%/b Connected through multi-purpose current transfomer

Ds862
3*380V

Three-phase three-wire active energy watt-hour meter

2

3*1.5(6)A  3*3(6)A

0.5%/b Connected through multi-purpose current transfomer

DS862
3*380V

Three-phase three-wire active energy watt-hour meter

2

3*5(20)A  3*10 (40)A
3* 15(60)A  3*20(80)A 3*30(100)A

0.5%/b Direct connection

DS862
3*100V

Three-phase three-wire active energy watt-hour meter

2

3*1.5(6)A  3*3(6)A

0.5%/b Connected through multi-purpose current voltage transfomer
DS864
3*380V
Three-phase three-wire active energy watt-hour meter 1 3*1.5(6)A  3*3(6)A 0.4%/b Connected through multi-purpose current transfomer
DS864
3*100V
Three-phase three-wire active energy watt-hour meter 1 3*1.5(6)A  3*3(6)A 0.4%/b Connected through multi-purpose current voltage transfomer
Dx862
3*380V
Three-phase four-wire active energy watt-hour meter 3 3*1.5(6)A  3*3(6)A 1%/b Connected through multi-purpose current transfomer
Dx862
3*100V
Three-phase four-wire active energy watt-hour meter 3 3*1.5(6)A  3*3(6)A 1%/b Connected through multi-purpose current voltage transfomer
Dx864
3*380V
Three-phase four-wire active energy watt-hour meter 2 3*1.5(6)A  3*3(6)A 0.5%/b Connected through multi-purpose current transfomer
Dx864
3*100V
Three-phase four-wire active energy watt-hour meter 2 3*1.5(6)A  3*3(6)A 0.5%/b Connected through multi-purpose current voltage transfomer
Dx865
3*385V
Three-phase three-wire active energy watt-hour meter 3 3*1.5(6)A  3*3(6)A 1%/b Connected through multi-purpose current transfomer
Dx865
3*100V
Three-phase three-wire active energy watt-hour meter 3 3*1.5(6)A  3*3(6)A 1%/b Connected through multi-purpose current voltage transfomer
Dx863
3*380V
Three-phase three-wire active energy watt-hour meter 2 3*1.5(6)A  3*3(6)A 0.5%/b Connected through multi-purpose current transfomer
Dx863
3*100V
Three-phase three-wire active energy watt-hour meter 2 3*1.5(6)A  3*3(6)A 0.5%/b Connected through multi-purpose current voltage transfomer

Main Technical data

1 . all technical requirements stipulated in standard GB/T 15283 Alternating Current Watt-hour Metersfor Active Energy(C lassed 0.5, 1 and 2), and the reactive energy watt-hour meter conforms to all technical requirements stipulated in standard GB/T15282 Reactive Energy Watt-hour Meter.

2 . The watt-hour meter can be made into two kinds; direction connection type and the type of connection through multi-purpose current transformer or multi­purpose voltage transformer.

3 . Start: under reference voltage,reference frequency and COAΦ=1(reactive energy watt-hour meter sinΦ =1). When the load current cant exceed the starting current in the table,the rotary disc of watt-hour meter can start and rotate continuously.

4 . Creeping: when current circuit of watt-hour meter has no current,and the voltage applied to voltage circuit is 80%~110% of reference value,the rotary disc of watt-hour meter rotates not more than 1 circle.

5 . Dielectric performance: when the watt-hour meter can with stand impact waeform(standard waveform 1.2/50 µ s)and impact voltage of 6kV peak value for 10 times respectively, it wont be damaged.The circuit­to-earth of watt-hour meter can withstand sine waveform of 2kV and 45~65HZ at AC voltage for 1min.

Outline & installation size